<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0">
<channel>
<title>News-Anhui Kangning Medical Products Co.,Ltd.</title>
<link><![CDATA[http://www.kangning-medical.com/index.php?case=archive&act=list&catid=2]]></link>
<description>11News-Anhui Kangning Medical Products Co.,Ltd.</description>
<item id="1">
<title><![CDATA[The first domestic &quot;epidural puncture needle&quot; arti]]></title>
<link><![CDATA[http://www.kangning-medical.com/index.php?case=archive&act=show&aid=33]]></link>
<description><![CDATA[&nbsp;For cancer patients tumor biopsy, this is the most common operation. But due to compression of the airway and tumor induced acute airway obstruction, which has no oxygen may make the minutes were divided into death. In the conventional tracheal intubation and first aid means declared to be invalid, doctors were clever use of &quot;a needle&quot; for supply of the body, and finally were pulled back from the jaws of death. This is recently occurred in the breathtaking scene of Bayi hospital operating room, also became the first epidural puncture needle &quot;artificial oxygen p…]]></description>
<pubDate>2015-07-27 08:59:25</pubDate>
</item>
<item id="2">
<title><![CDATA[How to improve the success rate of radial artery puncture]]></title>
<link><![CDATA[http://www.kangning-medical.com/index.php?case=archive&act=show&aid=32]]></link>
<description><![CDATA[&nbsp;Radial artery puncture is becoming more and more widely used in clinical practice, whether it is the anesthesia doctors, or the daily work of the medical personnel need to master this skill. How to master this skill in a short time and improve the success rate, the following is the author of some of the experience, hope to have some help to the clinical workers.
First of all, to understand certain anatomic relationship, the radial artery in the shallow surface of tendon of biceps brachii, brachial arteries and the terminal branches of, in radial neck at the beginning of the …]]></description>
<pubDate>2015-07-27 08:57:13</pubDate>
</item>
<item id="3">
<title><![CDATA[Puncture needle to replace the lead wire to open up many yea]]></title>
<link><![CDATA[http://www.kangning-medical.com/index.php?case=archive&act=show&aid=31]]></link>
<description><![CDATA[&nbsp;Of reporter of report from our correspondent Wang Xiaomei Herald reporter January 23, from the understanding of the First Affiliated Hospital of China Medical University, the hospital for the first time application RUPS100 puncture needle, the successful completion of a case of long segmental inferior vena cava occlusion, and duration of up to 30 years of operation, display the in Budd Chiari comprehensive sign mediated in the diagnosis and treatment of the international leading level.
Heilongjiang people in the 62 year old Mr. Li varicosity of abdominal wall and legs of low…]]></description>
<pubDate>2015-07-27 08:55:54</pubDate>
</item>
<item id="4">
<title><![CDATA[Continuous syringe use note]]></title>
<link><![CDATA[http://www.kangning-medical.com/index.php?case=archive&act=show&aid=30]]></link>
<description><![CDATA[&nbsp;Commonly used by the general animal with a syringe for 100 ml, 50 ml, 30 ml, 20 ml, 10 ml, and so on, while the continuous syringe has 50 ml, 25 ml, 5 ml, 0.5 ml.
General breeding households often use the animal with a syringe will be injected into the treatment of drugs when the use of ordinary syringes, vaccination will use a continuous syringe. Therefore, the quality of veterinary syringe is particularly important.
In the use of a veterinary syringe:
. before use should be check all parts of the welding is firm, glass tube has no cracks, flange drops the son (papillae) …]]></description>
<pubDate>2015-07-27 08:49:38</pubDate>
</item>
<item id="5">
<title><![CDATA[Needle free syringe into the clinical trial stage]]></title>
<link><![CDATA[http://www.kangning-medical.com/index.php?case=archive&act=show&aid=29]]></link>
<description><![CDATA[&nbsp;July 21, led by the second people&#039;s Hospital of Shenzhen City, Shenzhen Fourth People&#039;s Hospital, Longgang District People&#039;s Hospital of Shenzhen City, Baoan District of Shenzhen City People&#039;s Hospital, the University of Hong Kong, Shenzhen Hospital, eight hospitals in insulin without needle injection clinical test launch in Yinhua building held start control study of different insulin injection on patients with diabetes, glycosylated serum protein and 7 monitoring of blood glucose level, all in more intuitively from a clinical point of view is more &quot;…]]></description>
<pubDate>2015-07-27 08:45:10</pubDate>
</item>
<item id="6">
<title><![CDATA[Four development trends of China&#039;s medical device techn]]></title>
<link><![CDATA[http://www.kangning-medical.com/index.php?case=archive&act=show&aid=28]]></link>
<description><![CDATA[&nbsp;The State Food and Drug Administration recently issued the closely related normative documents of the medical device clinical evaluation technology of guiding principle and the domestic class III medical devices registration quality management system verification procedures (Interim), etc. Two and medical technology assessment, for the thorny problem of crack evaluation of medical equipment technology has taken an important step, but also aroused the industry to pay more attention to the medical instrument technology evaluation system.
In order to crack the difficult problem…]]></description>
<pubDate>2015-07-27 08:39:51</pubDate>
</item>
<item id="7">
<title><![CDATA[Inherent risks of medical devices]]></title>
<link><![CDATA[http://www.kangning-medical.com/index.php?case=archive&act=show&aid=27]]></link>
<description><![CDATA[&nbsp;&quot;By design factors, material factors, clinical applications, medical devices also exist inherent risks.&quot; City of drug adverse reactions and drug abuse monitoring center director Zhang Cunliang said. To this end, the majority of medical device users to correctly understand, to prevent all kinds of harmful events leading to human injury. According to reports, the inherent risks of medical devices include: design factors, restricted conditions, the cognitive level of science and technology, medical technology and other factors, there are different degrees of simplicity…]]></description>
<pubDate>2015-07-27 08:35:34</pubDate>
</item>
<item id="8">
<title><![CDATA[Business of medical devices adverse event monitoring is stil]]></title>
<link><![CDATA[http://www.kangning-medical.com/index.php?case=archive&act=show&aid=26]]></link>
<description><![CDATA[&nbsp;Recently, the State Food and Drug Administration issued the &quot;national medical device adverse reaction monitoring annual report (2014)&quot;. Report includes medical device adverse event report situation, medical device adverse event reporting statistical analysis, of catheter, specific electromagnetic wave treatment instrument, fumigation equipment three medical equipment products safety problems to take measures, comprehensively reflects the 2014 China medical device adverse event monitoring work.
Million population report reflects the situation in the provinces is not…]]></description>
<pubDate>2015-07-27 08:32:36</pubDate>
</item>
<item id="9">
<title><![CDATA[Medical instrument industry weekly: the basic standards of i]]></title>
<link><![CDATA[http://www.kangning-medical.com/index.php?case=archive&act=show&aid=25]]></link>
<description><![CDATA[&nbsp;Industry news and company announcements
1, the new version of the medical device classification rules to consider and pass
2, CFDA released 2014 medical device adverse event monitoring Annual Report
3, the State Food and Drug Administration issued the &quot;medical device naming rules (Trial)&quot; (Draft)
4, Qianshan medicine machine: plan for the three Huayi medical capital
5, Edan instruments: a new generation of color products completed CE certification
6, Guan Hao: biological and Zhuhai Xiangle signed a letter of intent to transfer of shares, fully open up the fiel…]]></description>
<pubDate>2015-07-27 08:31:25</pubDate>
</item>
</channel>
</rss>